Home BC580Lx (EXPLOSSION PROOF INDICATOR)
BC580Lx Ex weighing indicator is designed for weighing and control application in hazardous fields. The BC580Lx can be used as drum-filling, material transferring, level indicator and also can transfer the weight information in hazardous out to PLC or SCADA by digital or analog communication, integrating field display and remote transmission at the same time, is an economical but efficient weighing solution for hazardous application. Explosion proof grade : Exd [ ibⅡC ]ⅡB T6 Gb, Ex td A21 IP66 T80ºC
ENCLOSURE | Cast Aluminium | |||
|---|---|---|---|---|
APPLICATION | 2-speed material transfer mode, Setpoint comparison, Over/under, Check weigh, Reduction weigh, Peak force measurement, Gross/net fill | |||
SINGAL RANGE | -20Mv ~ +20mV | Signal Range | -20Mv ~ +20mV | |
MAX. SENSITIVITY | 0.5uV/d | Max. Sensitivity | 0.5uV/d | |
FS DRIFT | 3ppm/ºC | FS Drift | 3ppm/ºC | |
AD REFRESH RATE | 50 ~ 200Hz | AD Refresh Rate | 50 ~ 200Hz | |
DISPLAY | 7-digit 1’segment LED | |||
KEYPAD | 6 KEYS | |||
DISCRETE I/O | 2 INUTA; 3 Outputs (220V AC @ 5A) | |||
USART | COM1: RS232; COM2: RS485 | |||
SERIAL PROTOCOL | MOSBUS RTU, Command output, Continuous Output | |||
OPTION | 4~20mA/0~10V, Profibus DP | |||
POWER SUPPLY | 180~240V AC, 60Ma; 24V DC, 150mA | |||
OPERATING TEMPERATURE | 10ºC ~ +40ºC, Relative humidity: 10% ~ 90%, non-condensing | |||
Classified area: Class, Division 1 or 2, Group B, temperature code T6
Compact Panel Mount structure, save installation space
New generation of embedded high speed processor, strong on an-interface
Optimized digital filter and quick following technology
4~20mA/0~10V analog out available
Over/under limit alarming
Embedded material transfer control
Embedded Setpoint comparison function
Check-weigh control
Auto zero tracking available
Power-up zero available
Isolated RS232/RS485/ serial interface
Standard MONBUS RTU protocol
220V AC power supply (24V DC available)
Model | P.N | Description | |||||||
|---|---|---|---|---|---|---|---|---|---|
BC580Lx1 | 22000272 | Cast Aluminium, 2-in, 3 Relays Outputs, RS232/RS485, Red LED, 220V AC | |||||||
BC580Lx2 | 22000273 | Cast Aluminium, 2-in, 3 Relays Outputs, RS232/RS485, 4~20mA, 220V AC | |||||||
BC580Lx3 | 22000311 | Cast Aluminium, 2-in, 3 Relays Outputs, RS232/RS485, Profibus DP, 220V AC | |||||||
BC580Lx1 (DC) | 22000279 | Cast Aluminium, 2-in, 3 Relays Outputs, RS232/RS485, Red LED, 24V DC | |||||||
BC580Lx2 (DC) | 22000280 | Cast Aluminium, 2-in, 3 Relays Outputs, RS232/RS485, 4~20mA, 24V DC | |||||||
BC580Lx3 (DC) | 22000344 | Cast Aluminium, 2-in, 3 Relays Outputs, RS232/RS485, Profibus DP, 24V DC | |||||||
Parallel connection up to 4 load cells
304 stainless steel housing
IP66 protection rating
Corner adjustment function
Explosion proof grade: Ex iaⅡC T6 Ga
IP65 protection rating
Low profile, high accuracy
Hermetically sealed
Optional for alloy steel or stainless steel
Various capacities from 500kg to 15t
Class C3
Explosion proof grade: Ex iaⅡC T6 Ga
Applicable for gas and dust explosion-proof environment in zone 1 and zone 2
Modularized design & suitable for 35mm DIN mounting rail
For strain gauge load cell
Connection for 4-wire / 6-wire load cell
Explosion proof grade: [ EX ib Gb]ⅡC
IP65 protection rating
Flameproof protection type
Hydrogen group and representative substance
Max. surface temperature 85ºC
Explosion proof grade: Ex dⅡC T6